FDC Status


Bit Comments Condition Meaning
#7 Motor On (MO) (Still active 1s or 2s after the bit busy is cleared) 0: Motor off, 1: Motor on
#6 Write Protect (WPRT) (Updated after type 1 and write FdcCommands) 0: Not protected, 1: Protected
#5 Spin up sequence complete After type 1 FdcCommands 0: Non optimal rotation, 1: Optimal rotation
#5 Record type After a Read Sector command 0: Normal data mark, 1: Cleared data mark
#4 Record Not Found (RNF) error - 0: Ok, 1: RNF error
#3 Cyclic Redundancy Check (CRC) error - 0: Ok, 1: CRC error
#2 Track 00 After type 1 FdcCommands 0: Track <> 00, 1: Track 00
#2 Lost data After type 2 or type 3 FdcCommands 0: Ok, 1: Lost data
#1 Index Pulse (IP) After type 1 FdcCommands) 0: No pulse met, 1: Index Pulse met
#1 Data request After type 2 or type 3 FdcCommands 0: Not ready, 1: Ready for transfert
#0 Busy - 0: command being executed, 1: command finished